{"product_id":"breezaire-wkl-6000","title":"Breezaire WKL 6000 Wine Cellar Cooling Unit","description":"\u003cp\u003eThe Breezaire WKL 6000 Wine Cellar Cooling Unit is a self-contained, through-the-wall cooling system designed for properly insulated wine cellars up to 1,500 cubic feet. With a 6,000 BTU cooling capacity and an integrated Sentry III+ electronic control system, the WKL 6000 is designed for larger residential wine cellars and wine storage spaces.\u003c\/p\u003e\n\u003cp\u003eThe self-contained design combines the cooling components within a single cabinet and is intended for through-the-wall installation. The standard configuration exhausts warm condenser air through the rear of the unit into an appropriately ventilated adjacent space.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for cellars up to 1,500 cubic feet:\u003c\/strong\u003e Intended for properly insulated and sealed wine storage spaces within the manufacturer's recommended capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6,000 BTU cooling capacity:\u003c\/strong\u003e Provides cooling capacity for larger residential wine cellar applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-contained system:\u003c\/strong\u003e Cooling components are integrated into one cabinet for through-the-wall installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrough-the-wall installation:\u003c\/strong\u003e Designed for installation through a properly prepared wall opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSentry III+ electronic controls:\u003c\/strong\u003e Provides digital temperature monitoring and adjustable temperature settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50°F–60°F operating range:\u003c\/strong\u003e Provides an adjustable temperature range for wine cellar applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic humidity control:\u003c\/strong\u003e Helps manage moisture within the cellar environment as part of the cooling system's operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic defrost:\u003c\/strong\u003e Helps manage frost accumulation during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower outage protection:\u003c\/strong\u003e Includes control-system protection for power interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlocked-airflow protection:\u003c\/strong\u003e Includes a protective function for restricted airflow conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDesigned for Large Wine Cellars\u003c\/h3\u003e\n\u003cp\u003eThe WKL 6000 is rated for wine cellars up to 1,500 cubic feet when the enclosure meets the manufacturer's insulation, sealing, vapor-barrier, ventilation, and installation requirements.\u003c\/p\u003e\n\u003cp\u003eActual cooling requirements depend on more than cellar volume. Insulation quality, glass exposure, ceiling height, surrounding temperature, sunlight, door usage, and other heat loads can affect the required cooling capacity.\u003c\/p\u003e\n\u003cp\u003eFor installations approaching the maximum recommended capacity, proper sizing should be confirmed based on the specific cellar construction and environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eSentry III+ Digital Temperature Control\u003c\/h3\u003e\n\u003cp\u003eThe integrated Sentry III+ electronic controller provides digital temperature monitoring and adjustable settings. An LED display allows the cellar temperature to be monitored directly from the cooling unit.\u003c\/p\u003e\n\u003cp\u003eThe control system also incorporates protective functions designed to help manage operating conditions, including protection associated with power interruptions and restricted airflow.\u003c\/p\u003e\n\u003ch3\u003eSelf-Contained Through-the-Wall Design\u003c\/h3\u003e\n\u003cp\u003eThe WKL 6000 is designed as a self-contained cooling unit that installs through a suitable wall opening. This configuration does not require a separate remote condenser or field-installed refrigerant lines.\u003c\/p\u003e\n\u003cp\u003eThe condenser side releases warm air into the adjacent room. Adequate ventilation and sufficient clearance are therefore important to prevent warm exhaust air from recirculating back into the cooling system.\u003c\/p\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe wine cellar should be properly insulated and sealed.\u003c\/li\u003e\n\u003cli\u003eA suitable vapor barrier should be incorporated into the cellar construction.\u003c\/li\u003e\n\u003cli\u003eA properly prepared wall opening is required.\u003c\/li\u003e\n\u003cli\u003eThe warm-air exhaust must discharge into an appropriate adjacent space.\u003c\/li\u003e\n\u003cli\u003eThe exhaust area should provide adequate ventilation.\u003c\/li\u003e\n\u003cli\u003eRequired clearances around the cooling unit must be maintained.\u003c\/li\u003e\n\u003cli\u003eA suitable 115V electrical connection is required.\u003c\/li\u003e\n\u003cli\u003eThe intake and exhaust airflow paths should remain unobstructed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit should not be installed in an outdoor space or an area where condenser exhaust heat cannot properly dissipate. Review the manufacturer's installation instructions and site requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eFactory Modifications and Options\u003c\/h3\u003e\n\u003cp\u003eThe WKL 6000 can be ordered with several factory modification options for installations with specific routing requirements. Modified units are special orders and may have additional production lead times and different return or cancellation conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Air Out the Top (HAU):\u003c\/strong\u003e Routes condenser exhaust from the top rather than the standard rear configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCord Out the Back (COB):\u003c\/strong\u003e Routes the power cord from the rear of the unit rather than the standard configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Air Out the Top (CAT):\u003c\/strong\u003e Provides an alternate cold-air routing configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Drain Fitting (RDF):\u003c\/strong\u003e Provides a rear fitting for condensate drainage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack Series:\u003c\/strong\u003e Special-order configuration featuring an aluminum cabinet with a black finish.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFactory modifications can add production time and may make the unit non-returnable or non-cancellable after manufacturing. Confirm the desired configuration before placing an order.\u003c\/p\u003e\n\u003ch3\u003eOptional Breezaire Bottle Probe\u003c\/h3\u003e\n\u003cp\u003eAn optional Breezaire Bottle Probe is available for compatible WKL-series systems. The accessory is designed to monitor wine bottle temperature rather than relying only on the surrounding cellar air temperature.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Breezaire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e WKL 6000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Wine cellar cooling unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity:\u003c\/strong\u003e 6,000 BTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Cellar Capacity:\u003c\/strong\u003e Up to 1,500 cubic feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Type:\u003c\/strong\u003e Through-the-wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Self-contained\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e Sentry III+\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED readout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 50°F–60°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control:\u003c\/strong\u003e Automatic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefrost:\u003c\/strong\u003e Automatic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Exhaust Direction:\u003c\/strong\u003e Rear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Requirements:\u003c\/strong\u003e 115V, 60Hz, 9.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22\" H × 16.25\" W × 22.25\" D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 101 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 year labor \/ 5 years parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBreezaire WKL 6000 wine cellar cooling unit\u003c\/li\u003e\n\u003cli\u003eIntegrated Sentry III+ electronic control system\u003c\/li\u003e\n\u003cli\u003eStandard power cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories and factory modifications, including the Bottle Probe and alternate exhaust or drainage configurations, may be available separately.\u003c\/p\u003e\n\u003ch3\u003eCare and Maintenance\u003c\/h3\u003e\n\u003cp\u003eKeep the unit's air intake and exhaust areas clear of dust, debris, and other obstructions. Periodically inspect the surrounding installation area to ensure adequate airflow and ventilation remain available.\u003c\/p\u003e\n\u003cp\u003eMaintaining proper cellar insulation, sealing, and vapor-barrier conditions is also important for the cooling system to operate under the intended conditions. Follow the manufacturer's installation and maintenance instructions for additional service requirements.\u003c\/p\u003e\n\u003ch3\u003eImportant Sizing Note\u003c\/h3\u003e\n\u003cp\u003eThe stated capacity of up to 1,500 cubic feet assumes a properly constructed wine cellar and suitable operating conditions. Cellars with extensive glass exposure, direct sunlight, high surrounding temperatures, frequent door openings, or inadequate insulation may require additional cooling capacity.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, verify the cellar volume, construction, ambient conditions, electrical requirements, wall-opening dimensions, and available exhaust space to determine whether the WKL 6000 is appropriate for the installation.\u003c\/p\u003e","brand":"WCI Service","offers":[{"title":"Standard","offer_id":71923929448470,"sku":"WKL 6000","price":4071.0,"currency_code":"USD","in_stock":true},{"title":"Black Aluminum (Modified 4 weeks Lead Time)","offer_id":71923929481238,"sku":"WKL 6000-BLK","price":4344.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0925\/5944\/1942\/files\/BreezaireWKL6000WineCellarCoolingUnitFrontView.png?v=1791474118","url":"https:\/\/forgeandfern.com\/products\/breezaire-wkl-6000","provider":"Forge and Fern","version":"1.0","type":"link"}